Monday, August 12, 2019

ArchSmarter Course on Energy Optimization - $49 Limited Time Special

Check out this new ArchSmarter video course I created on energy optimization for architects. I think you will find significant value in this material....


Energy modeling and building performance simulation are critical tools to help you understand the impact of design decisions on your building's performance. These tools are also essential to demonstrate your building meets specific energy guidelines.

Autodesk Insight is an online tool from Autodesk that calculates building energy use and performance. It is integrated into Revit and provides visualizations on key building performance metrics.
Keep reading to learn more...

Tuesday, August 15, 2017

gbXML Certification and Validation

Autodesk is helping to define a new, more accurate, gbXML schema to improve the way industry is documenting and sharing data; specifically: geometry descriptions, envelope descriptions, schedules and systems.
"gbXML is an industry supported schema for sharing building information between disparate building design software tools."

As a "research partner" with gbXML, Autodesk is helping define the Level 3 compliance requirements and compliance tests.

This standard and validation process...

Sunday, April 23, 2017

Autodesk Insight 360 - Walls; Part 3

In the previous two posts on Insight 360 and walls, we looked at how conceptual and schematic wall constructs are applied when mass elements and Revit's wall elements are used. Those  posts can be found here:
In this post I want to highlight how Revit determines the Window to Wall Ratio (WWR). Early on in a project this value does not matter on the Revit side, as there is a dynamic input for WWR for each face (N,E,S,W) of the building. Thus, this input can be changed within Insight irrespective of the Revit model and it's settings.

First, let's see how we define WWR when using mass elements. I am using the same mass model from the "Part 1" post. In case it was not clear in that first post, the entire building is represented by a single mass element. That is interesting when you consider the Energy Analysis Model (EAM) resulted in separate vertical walls in the same plane; Exterior Walls and Underground Walls due to the Ground Plane setting in the Energy Settings dialog.


If we want to set a baseline value of 40% (per ASHRAE 90.1) we can do so in the Advanced Energy Settings dialog. Notice the related Target Sill Height and Glazing is Shaded options.


When the EAM is created, we see the analytical windows are added. In this selected example, the window is 201sf and the remaining above-grade wall is 302sf - thus, 40% of the wall is window. None of the below grade wall is considered in this equation.



When this EAM is pushed out to Insight 360, we see the BIM Setting for the four WWRs is 40%.

  • TIP: Notice how the BIM Setting always aligns with zero on the vertical scale.




The great thing about Insight 360 is we can dynamically adjust the WWR without needing to go back into Revit and make changes. In the image below, the Western WWR was adjusted to be 95%, which resulted in the Energy Cost Mean changing from $2.13 (sf/yr)  to a less efficient $2.25 (sf/yr).

  • FYI: The $2.13 value was based on a WWR range between 0% and 95%, and the $2.25 is based on a single input of 95%.



Quick closing tip... if you prefer EUI (kBth/sf/yr) over Cost (dollars/sf/yr), simply click on the circle in the upper left corner.



I have a few more posts in mind related to walls, so please stay tuned...



Monday, May 1, 2017

Autodesk Insight 360 - Walls; Part 7

As a follow up to my previous Insight 360 post, Autodesk Insight 360 - Walls; Part 6, it is helpful to know what happens when a Revit wall element does not have a thermal value (or one that is too low).

This only applies when Detailed Elements is checked in the Energy Setting > Advanced Energy Settings dialog,


If a material does not have a Thermal asset, it will not contribute to the wall assemblies thermal properties. Notice here, in the image below, that a Thermal asset may be deleted, The adjacent buttons allow a Thermal asset to be copied or replaced with another property.

  • For example, a wood stud wall could have the Thermal properties of batt insulation applied in place of the wood studs, which has much lower thermal properties alone. The drawback is that this trick does not account for the batt insulation in material take offs, but does not affect the total wall thickness either.


In this example, using the model from the previous post, I removed all the thermal assets associated with the materials used by the exterior wall as seen in the image below.


When I push the EAM out to Insight 360 I get an email stating that an error occurred and the model could not be processed. Notice, in the next image, the indication is that wall is too thin or the thermal properties are too low.


Once a model is in Insight 360 it is possible to select a surface and see "aim" number. If this were a large complex project with just a few walls causing the problem, I am not sure if there is a way to dial in quickly using this number.

Creating a schedule like the one below would be the best bet, looking for exterior walls with low or no thermal resistance.



Tuesday, April 25, 2017

Autodesk Insight 360 - Walls; Part 5


In the post we will explore the way Window to Wall Ratio (WWR) is derived when both Revit walls and mass elements define the Energy Analysis Model (EAM). In the previous two ports we looked at each separately.

The image below shows the model used in today's post. The same model with walls from the previous post along with the a mass element added to represent an addition.
Building elements with a mass added to represent an addition

To use both Revit elements and masses in the EAM the Energy Settings dialog must be accordingly as shown in the image below.

Tell Revit to use masses and building elements to create the EAM

Also in the Energy Settings dialog, the WWR can be set. This only applies to the mass element.

Seeing WWR for mass elements
The image below is the EAM as seen in Revit. The walls and windows are explicitly defined by the Revit elements, while the mass element has 40% glazing applied to the three exterior sided.

  • FYI: of course the mass element does not know how there will be a parapet so the wall area and WWR are off a little.


EAM in Revit

When pushed out to Insight 360 we see the BIM Setting matches what we saw back in Revit.

Results as seen in Insight 360

In addition to what was defined within Revit, Insight allows the overall WWR to be adjusted for each N/E/S/W face. Simply adjust the sliders to define a range until you are more confident in a specific value. While defining a rage, the Cost/EUI listed is the mean value.

One final note... as a test to see if I could, this entire post was created from my iPad. Everything, except the screen captures. I added the mass element in Revit, created the EAM and used Insight 360 all on the iPad.

The EAM in Revit shown on an iPad



Wednesday, April 26, 2017

Autodesk Insight 360 - Walls; Part 6

In the first two posts on Insight and walls, we looked at how conceptual and schematic wall constructs are applied when mass elements and Revit's wall elements are used. Those  posts can be found here:
In this post I want to highlight how Revit's materials can be used to define the thermal properties of a wall's construction.

In the Energy Settings > Other Options dialog, checking Detailed Elements tells Revit to use the thermal properties associated with each material used in the wall assemble.


Notice, the default Revit materials have a Thermal asset associated with them as seen in the image below. Also notice, the combined total of the wall assembly, based on thermal properties and the thickness of each layer, is listed in the Edit Assembly dialog. In this example, the selected wall type has an R value of about 32.


Before creating the EAM, as a test, I made sure and set the Schematic Types wall construction to an uninsulated wall, and no override in the Schematic Types section. This way we know the value within Insight is coming from the Material's thermal properties.

Below is a slightly more detailed model I used for this example.




This is what the EAM looks like. The jagged lines represent the thermal zoning... if you look closely you will see there is a below and above the ceiling. The EAM understands a space is not occupied when it's height is less than a specific value (5'-0" I think).

For the first example, I changed the thickness of the walls Rigid Insulation layer to 1" (it was 3"). When compared to the previous Edit Assembly image, notice the R value has changed from 32 to 23.



When pushed out to Insight we see the BIM Setting is properly positioned in the R-23 vicinity.



Back in Revit, I changed the Rigid Insulation thickness to a rather unusual 8", per the image below, which equates to R-53, to see what that looks like in Insight.


In this case, the BIM Setting is all the way to the right, which is to the right of the R-38 input.


I am told there are some limits to the rage for inputs when using materials to define a wall's thermal resistance, and in some cases the run will fail and send you an email explaining as much.

Earlier, I mentioned the EAM is tracking occupiable and unoccupiable spaces within the building. When an EAM is first created, Revit also creates an Analytical Spaces schedule as seen in the final image of this post. When your Revit model has Rooms/Spaces, their names and numbers are also listed with each sapce. In this case, the rows lacking this information are the plenum spaces (or mechanical shafs, plumbging spaces, etc.).
  • FYI: due to these extra spaces, the total area listed would not match the building area.











Friday, November 3, 2017

AIA Minnesota Convention 2017; Dynamic Energy Optimization with Revit and Insight 360

I am excited to be presenting again at the Minnesota AIA Convention on Autodesk's energy modeling workflow later this month. I believe this workflow is one of the most powerful, yet most overlooked, energy optimization tool for architects. Using Revit and the cloud-based Autodesk Insight, any project team-member can play an important role in decisions at multiple stages in a project.

I gave a similar presentation last year in Phoenix Arizona, where the attendees voted the session into the 'top ten' list; RTC-NA Top Ten blog post. I have also been doing staff training on this subject in our Duluth and Minneaoplis offices recently; read most about that here: Increased Efficiency Through Training; For Staff and Buildings.



Session details:
  • AIA-MN Convention 2017
  • Event 39 (TH39) Dynamic Energy Optimization with Revit and Insight 360
  • Thursday, November 16, 2017, 08:30 am - 10:00 am
  • Minneapolis Convention Center
Additionally...

Friday, April 21, 2017

Autodesk Insight 360 - Walls; Part 2

Following yesterday's discussion, Autodesk Insight 360 - Walls; Part 1, on how Revit determines analytical walls from mass elements, I will now shift our attention from mass elements to wall elements.

As seen in the first image below, I created the same "award-wining design" in this post, based on the massing in the previous installment, Notice that this more developed design has parapets, which are defined by a single wall extending from Level 1 up a certain distance above the roof plane.

Revit model created with wall, floor and a roof elements.
When the Energy Analytical Model (EAM) is created in Revit, we see similar results when compared to the previous massing exercise. We have Exterior Walls and Underground Walls.


Exterior Walls element selected in the EAM


Underground Walls element selected in the EAM
If you are paying close attention and comparing the wall area numbers with the previous post you may have noticed the area for the same exterior wall is not quite the same. The reason is that the parapets are automatically omitted from the "exterior walls" equation. The image below shows the EAM has converted the parapet walls to Shade surfaces. This is perfect!

  • It is not as accurate to simply take the literal wall, floor and roof areas and plug them into an equation.


Shading element selected in the EAM
BTW, we can control the visibility of the various parts of the EAM from the Visibility/Graphics Overrides dialog as seen in the image below. This is what I did to create the the images above.

Visibility/Graphics Override dialog for 3D Energy Model view
Once we push this "Revit Elements" based model to Insight we understand this more detailed design iteration results in a more accurate Cost/EUI. It is interesting to see that the super simple thermally zoned mass analysis,from the previous post, offered reasonable close preliminary information.

Walls-based model and Mass-based model in Insight
Setting the Mass Exterior Wall construction to uninsulated also applies to Revit's wall elements. This may be a little confusing since the word "Mass" is in the name of the parameter you are adjusting. When pushed out to Insight, we see the "BIM Setting" is properly positioned at uninsulated for the Wall Construction input.

Insight 'BIM setting' aligns with Revit setting

Like yesterday, I went in and applied an override in the Schematic Types dialog (within the Energy Settings dialog) and selected an R38 construction. When we subsequently push a model to Insight there is something important to understand... the EAM is totally static geometrically and in terms of information. So, if we don't delete and recreate the EAM this new change would not influence the analysis.

When pushing the model to Insight, we are conveniently prompted to automatically recreate the EAM as shown in the image below. However, I think it is best to do it manually and visually inspect it for any irregularities; for example, someone decided to model all the wall types just outside the building.

Insight export prompt within Revit
After deleting and recreating the EAM we get the expected results in Insight!

Insight 'BIM setting' aligns with revised Revit setting
This workflow represents a simple yet powerful opportunity to enhance the performance of most any project being developed in Revit. Like any tool, taking the time to understand it's various parts is key to getting accurate results. Continuing the focus on walls, in future posts, I will talk about using Revit materials to define the thermal properties in a wall, and then another post will look at some things to keep in mind when it comes to Window to Wall Ratio (WWR). So stay tuned for more...

Sunday, May 7, 2017

Autodesk Insight 360 - Floors; Part 2

Following my previous post, Autodesk Insight 360 - Floors; Part 1, I want to share a few more details about how analytical floors are automatically derived from the Revit model. I will close with a brief mention of what Insight's main competitor, Sefaira, requires in these situations.

Today's example will be based on the model shown below. This model has a balcony defined by extending the main level 2 floor outside the building. There is a similar situation happening with the roof, above the balcony.
Additionally, a portion of the level 2 floor is sloped as shown in the building section below.


When the Energy Analytical Model (EAM) is created within Revit, we see how the various conditions just mentioned are handled. Notice that balcony, and its roof, are automatically separated and defined as a shade surface (same as the parapet as discussed in a previous post). Additionally, the analytical floor is sloped in the EAM.


Although a great product, Sefaira is not this simple as they want you to model things, in Revit, in a very specific way: How to model balconies, roof overhangs, and outside patios for Sefaira. You can model this way and Revit will still create the EAM properly. I like the fact that Insight is more flexible. This flexibility also means the results are more accurate when you consider some will forget, or not take the time to understand, these specific modelling requirements. Although I could not verify this just now, last I checked Sefaira did not support sloped floors.

With Revit and Insight 360, as long as there are no major gaps (e.g. a 10' hole in the shell) in the model the EAM generally turns out accurate and ready for analysis. This is great as this can be done in the main Revit model, even while the design team is cranking on the SD, DD or even CD's!

Fun stuff.

Thursday, April 20, 2017

Autodesk Insight 360 - Walls; Part 1

Autodesk Insight 360 is a powerful energy modeling tool in conjunction with a Revit model. To help realize it's full potential, I thought I would offer up a series of short posts which focus on specific elements of Revit, Insight and energy modeling. You may be surprised at how simple, yet powerful, this feature set can be!

I plan on writing a few short posts to cover just walls in the content of energy modeling. I will start with these three topics:
  • Massing
  • Revit walls
  • Window to Wall Ratio (WWR)
For this post, I want to highlight how Revit defines exterior wall construction, from mass elements, when generating the Energy Analytical Model (EAM).

We can perform an energy analysis against simple Revit massing. In the images below I created a super simple mass. This mass extends below level 1 to define a basement area. I selected the mass and used the Mass Floors button on the Ribbon to specify Basement and Level 1 for this specific element.
  • FYI: If I did not specify Mass Floors, the entire element would be seen as a shade surface. This is helpful when representing adjacent buildings.
Before we get to Insight we need to create an EAM in Revit. There is a lot of cool stuff happening here. For now, given our "wall" focus, we will notice from the next two images that the EAM understands above grade and below grade walls. In the next post we will see it even understands parapet walls when using Revit elements (i.e. not massing).

EAM with an exterior wall selected

EAM with below grade wall selected
The thermal properties of a wall are defined in the Energy Settings dialog. In the Other Options sub-dialog, there are three successive options; Conceptual Types, Schematic Types and Detailed Elements. By default, Revit uses the Conceptual Types settings as we will see...

The image below shows an extreme example of no insulation so it is super clear what is happening when we get into Insight. Notice, this is set in Conceptual Types.

Exterior walls set to uninsulated in Conceptual Types
When we get to Insight we see the "BIM setting" (triangle symbol) for wall construction is aligned with the uninsulated end of the spectrum per our selection within Revit.
  • FYI: I used to think the "BIM setting" replaced the input it aligned with on the Cost Range slider, but as you can see below it is just positioned along side it; notice Uninsulated is still a separate option even though it is the same value as the "BIM setting".

Wall construction result in Insight

If we apply an override in Schematic Types, this takes precedent over the Conceptual Types setting... but just for the categories selected. In the example below, only walls are overriding the Conceptual Types settings. Here I go towards the other end of the spectrum with an R38 wall construction.

Wall value override selected in Schematic Types
Back in Insight we see the "BIM Setting" has moved accordingly.

Wall construction result in Insight
The Conceptual Types options are somewhat limited, Schematic Types have a lot more options, and when we get to using Revit materials to define thermal properties there is no limit to the number of options we could have (as we will see in a later post).

I was working with one of our architects this week and she noticed that Schematic Types even has a Straw Bale option as seen in the image below!

Straw bale wall construction option within Schematic Types
The great thing about Insight is we can dynamically modify these inputs apart from the Revit model. However, this information is helpful to understand so you can set some baseline inputs, e.g. based on your state's energy code or ASHRAE 90.1, within your template. And, as the project progresses and decisions are made, those decisions can be captured within the BIM.